DasstechDasstechDasstechDasstech
  • Company
    • CEO Greetings
    • Vision 2030
    • CI/BI Introduction
    • DASS History
    • Directions
  • Business Field
    • Solar
      • Solar Inverter
        • DASSTECH Inverter Technology
        • Inverter
        • Inverter Enclosure Box
        • Monitoring system
      • Solar power plant construction
        • Project Introduction
          • Operation & Maintenance Service
        • Construction Cases
          • Solar Photovoltaic Power Plant
          • Public Institution
          • General Housing
          • Rebuilding Service
    • Charger
      • EV Charger Power Module
        • EV Charger Power Module Technology
        • Configuration Diagram and Specs
      • EV Charger
        • Electric Vehicle Charger Technology
        • Product Feature
      • Bidirectional Charger/Discharger
        • Battery Cell Charger/Discharger Technology
        • Configuration Diagram and Specs
    • Battery
      • Battery Packaging
        • Battery Packaging Technology
        • Configuration Diagram and Specs
      • Energy Storage System
        • Energy Storage System Technology
        • Configuration Diagram and Specs
  • R&D Centre
    • Research Institute
    • Achievements
  • DASS News
    • Recruitment
      • People We’re Looking For
      • Recruit
    • News
      • News
      • Notice
  • Customer Support
    • Service
    • Online Consulting
    • FAQ
    • Data Room

DSP-3360KSHK-(NJ)

  • dass-60i-j
  • dass-50i
  • dass-50i-nj
  • dass-60i
  • dass-100a-lv
  • dass-100a-nj
  • dass-110i-j
  • dass-125i
  • DSP-33125KMHK-(J)
  • DSP-33125KSHK-(NJ)
  • sci-500
  • sci-1000
  • Inverter Enclosure Box
    • Three-phase Enclosure Box (for 15kW~30kW)
    • Three-phase Enclosure Box (for 50kW~60kW)
    • Three-phase Enclosure Box (for 125kW)
    • Three-phase Enclosure Box (for 125kW)(NJ)
  • monitoring system
    • RTU
      • soleaf-any+
      • DSR-009-OD
    • Control Service
  • DSP-3360KSHK-(NJ)
  • 3.5i_K6V1C/P
  • DSP-33125K12MHK-(J)
  • DSP-33125KSHK-A(NJ)
  • 3.5i_K6V1
  • dass-20i-15k
  • dass-20i-20k
  • dass-20i-20k-nj
  • dass-25i-25J1
  • DSP-3325KMHK-(J)
  • dass-25i-nj
  • dass-35i
  • DSP-3335KMHK-(J)
  • dass-35i-nj
Home main-new solar Solar Inverter DSP-3360KSHK-(NJ)
Company
  • Compnay
  • Business Field
  • R&D Centre
  • DASS News
  • Customer Support
CEO Greetings
  • CEO Greetings
  • Vision 2030
  • CI/BI Introduction
  • DASS History
  • Directions
  • DASSTECH Inverter Technology
  • Inverter
  • Inverter Enclosure Box
  • Monitoring System
  • Inverter
  • Inverter Enclosure Box


  DSP-3360KSHK-(NJ)
DASS Tech’s 60kW Transformer-less Three-Phase String Inverter,
Based on the Proven i-Solution Platform

  • 60 kW · Single MPPT
    Simple Configuration with 1 MPPT · 1 DC Input for Stable Operation
  • Transformer-less Three-Phase String Inverter
    Compact Design with Minimized Conversion Losses
  • High Efficiency of 98% or Higher
    Best-in-Class Power Conversion Efficiency
  • IP66 Outdoor Protection Rating
    Optimized for Waterproof and Dustproof Outdoor Operating Environments
  • Ground Fault & Insulation Detection + Grid Support
    RCMU / KS C 8565 / LVRT / Power Factor & Active Power Control
  • Front LCD Monitoring
    Graphic LCD + LEDs · Instant On-site Status Check
  • Smart Forced Air Cooling
    Stable Heat Dissipation with Smart Airflow Control
  • Compact Size
    650 × 750 × 336.5 mm
Input Specifications
Start-up Voltage (Vdc) 300V
Operating Voltage Range 200V ~ 1000V
MPPT DC Voltage Range 460V ~ 800V
Rated Voltage (Vdc) 630V
Maximum Open Circuit Voltage (Vdc) 1000V
Maximum Input Current (A) 132.8A
Input Terminal 1EA
MPPT Control Terminal 1EA
Control Method Maximum Power Point Tracking (MPPT) Control, PWM Method
Input Blocking Capacity 150A (2)
Output Specifications
Rated Output Capacity (kW) 60kW
Rated Voltage (Vac) Grid Voltage (AC380V +10%, -10%)
Frequency Fluctuation Rate (Hz) Grid Frequency (60Hz +1.5Hz, -2.5Hz)
Power Factor (%) 0.98 or higher (+0.9 ~ -0.9)
Anti-Islanding Method Within 0.5 seconds, restart 5 minutes after power restoration
Overload (%) 110%, 10 Minutes
Efficiency (%) Max 98% or Higher
Total Harmonic Distortion Total 5% or Less (3% or Less for Each Order)
Reactive Power Control Active Voltage Control, Output Control
Output Blocking Capacity 120A(3)
Structure
Cooling Method Smart Forced Air Cooling Type (FAN)
Ingress Protection rating (IP grade) IP66 (Outdoor Type)
External Dimensions (WxHxD, mm) 650 X 750 X 336.5
Total Weight (kg) 62kg
External Interface RS485
Service Environment Ambient Temperature : -20 ~ 50°C, Storage Temperature : -20 ~ 65°C, Humidity : Relative Humidity 90% R.H. or Less (No Dew Formation)
Protection Function Input Overvoltage, Output Short Circuit, Overload, Inverter Overheat Protection, DC Output Leakage Prevention, Isolated Operation Prevention, LVRT, Grid Overvoltage / Low Voltage Protection, Grid Overfrequency / Low Frequency Protection
Other Function PV Insulation Resistance Monitoring, Relay Fault Monitoring, Insulation Condition Monitoring, Residual Current Monitoring (RCMU)
Junction Box FUSE Rating Not Applicable (Junction Box Excluded)
Commercial Power Not Required
Certification KS Certification
Notes (1) Junction Box Excluded (2) DC SWITCH (based on rating 450V) (3) RELAY Blocking Capacity

Related documents

Number Download Title
1
Special Features - DSP-3360KSHK-NJ
  • 1

Address : 81, Yangcheongsongdae-gil, Ochang-eup, Cheongwon-gu, Cheongju-si, Chungcheongbuk-do, Republic of Korea (HQ)
Telephone: 043-218-5670 / AS : 1588-7468 / FAX : 043-218-5671
Refusal Privacy PolicyRefusal of Unauthorized Collection of Emails
Copyright ⓒ DASSTECH. All rights reserved.
  • Company
    • CEO Greetings
    • Vision 2030
    • CI/BI Introduction
    • DASS History
    • Directions
  • Business Field
    • Solar
      • Solar Inverter
        • DASSTECH Inverter Technology
        • Inverter
        • Inverter Enclosure Box
        • Monitoring system
      • Solar power plant construction
        • Project Introduction
          • Operation & Maintenance Service
        • Construction Cases
          • Solar Photovoltaic Power Plant
          • Public Institution
          • General Housing
          • Rebuilding Service
    • Charger
      • EV Charger Power Module
        • EV Charger Power Module Technology
        • Configuration Diagram and Specs
      • EV Charger
        • Electric Vehicle Charger Technology
        • Product Feature
      • Bidirectional Charger/Discharger
        • Battery Cell Charger/Discharger Technology
        • Configuration Diagram and Specs
    • Battery
      • Battery Packaging
        • Battery Packaging Technology
        • Configuration Diagram and Specs
      • Energy Storage System
        • Energy Storage System Technology
        • Configuration Diagram and Specs
  • R&D Centre
    • Research Institute
    • Achievements
  • DASS News
    • Recruitment
      • People We’re Looking For
      • Recruit
    • News
      • News
      • Notice
  • Customer Support
    • Service
    • Online Consulting
    • FAQ
    • Data Room
Dasstech